Yağlı Tip Akım Trafoları

Diğer Yağlı Tip Akım Trafoları

TANK TYPE OIL IMMERSED CURRENT TRANSFORMERS

Current transformer (CT) is used for measurement of Current & protection of major components and to provide continuity of operation in power system. When current in a circuit is too high to directly apply to measurement or protection relays, a current transformer produces a reduced current accurately proportional to the current in the circuit, which can be conveniently connected to measuring and recording instruments. Current transformer also isolates the measuring instruments from what may be very high voltage in the monitored circuit. It commonly used in metering and protective relays in the electrical power industry.

EMEK manufactures oil/paper insulated instrument transformers up to 550kV nearly 100.000 units since 1969.

Features of this design and contraction include:

  • Hermetically Sealed Construction

  • High Seismic Performance

  • Stainless Steel, Aluminium and/or Hot deep galvanized metal parts

  • Durability in extreme weather conditions

  • Long life time expectancy

Frequency : 50Hz, 60Hz

Standards : TSE, IEC, ANSI, GOST, BS&AS and other standards upon request

Insulators : Porcelain or Composite Polymer Insulators

Insulating Oil : Mineral oil in conformity with standards

Maintenance : Maintenance free

Spare Parts : No special tools, no serviceable parts or spare parts are required

TypesAT-24AT-36AT-72,5AT-125AT-145AT-170AT-245AT-420
Highest System Voltage24 kV36 kV72,5 kV123 kV145 kV170 kV245 kV420 kV
One minute power frequency voltage50kv rms70kV rms140kV rms230kV rms275kV rms325kV rms460kV rms630kV rms
Lightning impulse voltage125 kV Peak170 kV Peak325 kV Peak550 kV Peak650 kV Peak750 kV Peak1050 kV Peak1425 kV Peak
Rated frequency50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz
Short time thermal current50kA/1sec50kA/1sec50kA/1sec50kA/1sec50kA/1sec50kA/1sec50kA/1sec50kA/1sec
Dynamic withstand current125kA, peak125kA, peak157,5kA, peak157,5kA, peak157,5kA, peak157,5kA, peak157,5kA, peak157,5kA, peak
Total Creepage Distance25/31mm/kV25/31mm/kV25/31mm/kV25/31mm/kV25/31mm/kV25/31mm/kV25/31mm/kV25/31mm/kV
Primary CurrentUpto 2000A & higher currents can also be supplied on requestUpto 2000A & higher currents can also be supplied on requestUpto 4000A & higher currents can also be supplied on requestUpto 4000A & higher currents can also be supplied on requestUpto 4000A & higher currents can also be supplied on requestUpto 4000A & higher currents can also be supplied on requestUpto 4000A & higher currents can also be supplied on requestUpto 4000A & higher currents can also be supplied on request
Technical Details
Manuals
Type Tests
References
Brochures

Frequency

  • 50 Hz, 60 Hz

Secondary Current

  • 1 A, 2 A or 5 A, others on request.

Primary Current

  • up to 4000 A

Thermal and Dynamic Ratings

  • Short time thermal current ratings up to 50 KA/ 3 sec and dynamic current ratings up to 125 KA peak.

Continuous Thermal Current

  • 1.2 x In continuous (up to 2.0 x In or higher on request).

Insulation

  • Oil impregnated paper, high dielectric strength, low dielectric losses.

  • Graded layers with well rounded edges enable a uniformly distributed field over the whole unit.

Insulating Oil

  • The insulating oil is mineral oil in conformity with IEC 60296.

  • Before impregnation, moisture and gases are removed from the oil by special processes.

  • Drain plug for taking samples and oil refilling facilities are provided on request.

  • Floating type oil level indicator is standard supply.

Oil Impregnation

  • Heat and vacuum are applied to the fully insulated windings after assembly of the current transformer for drying purposes, followed immediately by the oil impregnation procedure.

Hermetic Seal

  • Oil volume variations are compensated with stainless steel bellows placed in the head of the transformers. With this facility there will be no contact between air and oil in the transformers.

  • The dielectric strength will remain unchanged for the life time of the CT.

Bushings

  • Brown, Grey glazed porcelain or polymer.

Primary Terminals

  • Primary terminals are made from tin plated copper or aluminium.

  • Vertical and horizontal primary terminals are available.

  • Dimensions depend on rated primary current.

  • Stud, nema pad or clamp type primary terminals are available.

Cores

  • Grain oriented silicon steel is used.

  • The core shapes are toroidal with or without air gap.

  • Electrolytic copper suitable to withstand rated continuous current and short time thermal current is used for primary winding.

  • Enamelled electrolytic copper wire is used for Secondary winding.

Bracelets

  • All bracelets used on transformers are made from aluminium alloy.

Head

  • The housing head is fabricated from corrosion protected aluminium.

  • Every housing is subject to pressure and vacuum test before assembly.

Base Plate

  • Base of the transformers are fabricated from steel and galvanised.

Name Plate

  • Name plates are stainless steel and weatherproof.

Secondary Terminal Box

  • Hinged type boxes are used and are sealable on request. They are made of galvanized steel or stainless steel.

  • Clamp type secondary terminals are used. Other secondary terminals are available on request. Earthing

  • Earthing terminals are located on the base of the transformers.

  • Clamp type terminals are available on request.

Painting

  • External surface of the transformers, which are already corrosion protected, are additionally painted grey. Other colours are available on request.

Earthquake Design

  • Standard design is up to 0.6g.

Ambient Temperature

  • Standard design is suitable for temperature range -50 °C to +50°C. Other ranges on request. Mechanical Strength

  • Applied load to the primary terminal in horizontal and vertical is in conformity with related IEC standards.

Altitude

  • Standard design is suitable up to 1000 m above sea level.

Optional Accessories

  • Capacitive tap

  • Steel support structure

  • Primary connectors

  • Marshalling box

Maintenance

  • Maintenance free, simple recommendations;

  • Clean the porcelain bushing at regular intervals depending on the degree of pollution.

  • Ensure that there is no oil leakage.

Spare Part & Special Tools

  • There are no user serviceable parts, therefore no spare parts or special tools are required for maintenance.

Assembly

  • Before the assembly, following visual checks should be made;

  • There are no oil leaks,

  • The porcelain is not damaged,

  • The aluminium protective cover on the bellows is not damaged,

  • There is no damage on the primary terminals,

  • The oil level indicator indicates sufficient oil level.

Packing

  • The transformers are packed in rugged wooden crates which are suitable for overseas transportation.

  • The transformers are encapsulated in polyethylene covers to keep them from environmental effects.

  • Wooden crates can be lifted by either a fork lift or by a crane with slings.

  • Other technical specifications may be available upon request.
Balıkhisar Mahallesi, Köyiçi Kümeevleri No: 574, Akyurt, 06750 Ankara - Turkey
(+90) -312 -398 -0181
(+90) -312 -398 -0474
emek@emek.com.tr
http://www.emek.com.tr
Yararlı Linkler
Şirket Profili
Kurumsal Kimlik
Temsilcilikler
Sıkça Sorulan Sorular
Teklif İsteme Formu
KVKK Başvuru Formu
Basın Odası
İletişim
Hakkımızda

Emek bağımsız, uluslararası çalışan bir ölçü transformatörleri üreticisidir.

Güvenilir ve yüksek kalitede ürünleri yerel ve uluslararası laboraturarlarda defalarca test edilmiştir. Deneyimi yarım asırdır sistemde çalışan transformatörler ile sağlamlaşmış, her geçen gün kendini geliştirmiş ve yenilemiştir.

Copyright © 2020. Emek.com.tr All rights reserved.Terms of UsePrivacy Policy